 FLAT RIBBON WIREstarting of main content Single Core Wire

                             Single Core Wire
Flat Ribbon Wire

UL STYLE       : 2468
Rating             : 80 °C, 300V (UL); 90 °C, 300V (CSA)
Standards       :  UL 758, CSA C22.2 No.210.2
Usage             :  For internal wiring of audio/video/multimedia equipment

Conductor Insulation Conductor resistance at 20oC (Max) 
W
/km
Approx. weight

kg/km

Unit Length

(m)

Type No Size

AWG

Stranding

 No./mm

Diameter

 (mm)

Insulation
Thickness
(mm)
Thickness

 (mm)

Diameter

 (mm)

TASC 2 26 7/0.16  0.48 0.41 1.30 2.80 139 6 305
3 4.30 10
4 5.80 13
5 7.30 16
6 8.80 19 153
7 10.30 23
8 11.80 26
9 13.30 29
10 14.80 32
11 16.30 36
12 17.80 39
13 19.30 42 153*
14 20.80 45
15 22.30 48
16 23.80 52
17 25.30 55
18 26.80 58
19 28.30 61
20 29.80 65
*Single Layer Coil

1.Product Description

a) Conductor : Tinned Annealed Copper wire (TA) or Tin Over Coated Tinned Annealed stranded Copper wire (TASC)
b) Insulation : Heat resistance leadfree PVC. Black colour

2.Features

a) Flammability : VW-1 (UL), FT1 (CSA), -F- (DENTORI).
b) Easy insertion to through-holes of PCB
c) Can be used with Insulation Displacement Contact(IDC) connectors

3. Wire Marking

AWM E41447-HCS STYLE 2468 26AWG VW-1 HITACHI CSA AWM LL49508
I A/B 90C 300V FT1 HCS -F- LF
**Conductor Size

4.Safety Standards No.

a) UL : E41447, CSA : LL49508, F-Mark : F-HCS1-003(2-7c), F-HCS1-012(8c).

5. Ordering Information

a) Contact us at mailto:sales@hitachicable.com.sg